{"product_id":"trendnet-ti-s12048-industrial-din-rail-power-supply-150w","title":"TRENDnet 150W AC to DC Industrial DIN-Rail Power Supply (TI-S12048)","description":"\u003c!-- OVERVIEW \/ DESCRIPTION --\u003e\n\u003cdiv class=\"product-description\" style=\"margin-bottom: 25px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eTRENDnet TI-S12048\u003c\/strong\u003e is a high-efficiency AC-to-DC industrial DIN-rail power supply with built-in Active Power Factor Correction (PFC) designed to optimize performance for mission-critical network deployments. Engineered specifically for high-draw environments, the upgraded V2 architecture supplies up to 150W of continuous power (48V–56V DC, 3.12A) to high-power industrial Power over Ethernet (PoE) equipment, including managed switches, multi-gigabit injectors, and heavy-duty outdoor PTZ surveillance cameras.\u003c\/p\u003e\n\u003cp\u003eEnclosed in a rugged, IP30-rated metal housing with an integrated TS-35 DIN-rail mounting clip, the TI-S12048 is designed for rapid installation inside standard automation panels and traffic enclosure cabinets. It features a fanless, passive cooling design and an intelligent multi-layered safety matrix that includes automated recovery from short circuits, overloads, and extreme thermal spikes, ensuring flawless 24\/7 infrastructure stability.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- KEY FEATURES --\u003e\n\u003cdiv class=\"product-features\" style=\"margin-bottom: 30px;\"\u003e\n\u003ch3 style=\"font-size: 1.3em; border-bottom: 1px solid #ccc; padding-bottom: 5px; color: #333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.6;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpgraded 150W High Output:\u003c\/strong\u003e Delivers clean, continuous power (48V to 56V adjustable output range, 3.12A) optimized perfectly for high-budget PoE+ and PoE++ applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActive Power Factor Correction (PFC):\u003c\/strong\u003e Integrated active controller increases power supply efficiency and eliminates reactive power loss to stabilize line currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh Weather Endurance:\u003c\/strong\u003e Engineered with silent, fanless natural convection cooling to operate seamlessly under extreme temperatures ranging from -25° to 70°C (-13° to 158°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e150% Peak Load Headroom:\u003c\/strong\u003e Advanced power engineering handles startup inrush currents and dynamic peak demands safely without tripping systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart DC OK Diagnostic Relay:\u003c\/strong\u003e Features built-in hardware relay dry contacts to continuously report hardware line health and instantly signal backend alert infrastructure if power drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Failure Protection:\u003c\/strong\u003e Comprehensive self-recovery protection systems safeguard your network against unexpected short circuits, overloads, over-voltage spikes, and over-temperature occurrences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- PRODUCT VIDEO --\u003e\u003c!-- SPECIFICATIONS TABLE --\u003e\n\u003cdiv class=\"product-specifications\" style=\"margin-bottom: 25px;\"\u003e\n\u003ch3 style=\"font-size: 1.3em; border-bottom: 1px solid #ccc; padding-bottom: 5px; color: #333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; font-size: 0.95em;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f5f5f5;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left; font-weight: bold; width: 30%;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left; font-weight: bold;\"\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafafa;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eInput Specifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAC Input: 90 – 264V AC, 47 – 63Hz, 2.5A\u003cbr\u003eDC Input: 127 – 370V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eOutput Capacity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePower: 150W continuous max power\u003cbr\u003eVoltage: 48 – 56V adjustable output range\u003cbr\u003eCurrent: 0 – 3.12A max continuous load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafafa;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eInterface \u0026amp; Layout\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHeavy-duty removable screw-terminal block slots\u003cbr\u003ePower status green LED indicator\u003cbr\u003eIntegrated TS-35\/7.5 or TS-35\/15 DIN-rail mounting tracks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003ePower Performance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eActive Power Factor Correction (PFC)\u003cbr\u003ePeak Load: 150% peak overhead capacity\u003cbr\u003eCooling: Passive free-air convection (completely fanless)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafafa;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eProtection Metrics\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eShort Circuit protection (Auto-recovery mode)\u003cbr\u003eOver Power \/ Over Current protection\u003cbr\u003eOver Voltage protection\u003cbr\u003eOver Temperature automatic protection shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eDiagnostic Contacts\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eBuilt-in \"DC OK\" dry relay diagnostic contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafafa;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eHousing \u0026amp; Environment\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIP30-rated industrial-grade metal enclosure\u003cbr\u003eOperating Temp: -25° to 70°C (-13° to 158°F)\u003cbr\u003eOperating Humidity: Max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40.5 x 125 x 103.3 mm (1.6 x 4.9 x 4.0 in.)\u003cbr\u003e556 g (1.22 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafafa;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px; font-weight: bold;\"\u003eCompliance \u0026amp; Testing\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCE, FCC, LVD, UL 62368-1 approved safety listings, CB IEC 62368-1\u003cbr\u003eBuilt with 100% full-load burn-in factory testing cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"TRENDnet","offers":[{"title":"Default Title","offer_id":38205375053975,"sku":"TI-S12048","price":561000.0,"currency_code":"MMK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0513\/8205\/9159\/products\/trendnet-ti-s12048-industrial-din-rail-power-supply-150w.jpg?v=1780990633","url":"https:\/\/ict.com.mm\/products\/trendnet-ti-s12048-industrial-din-rail-power-supply-150w","provider":"ICT.com.mm","version":"1.0","type":"link"}