{"product_id":"santak-castle-2k-online-ups-c2k-uni","title":"SANTAK Castle 2K Online UPS (C2K UNI)","description":"\u003cp\u003eDefend your high-value computer servers, medical instruments, and networked storage hardware against erratic grid issues with the professional \u003cstrong\u003eSantak Castle 2K Online UPS (C2K UNI)\u003c\/strong\u003e. Built utilizing high-performance true online double-conversion architecture, this robust tower uninterruptible power supply ensures a steady pure sine wave output by isolating attached devices from raw electrical irregularities. Boasting a zero-millisecond transfer delay, a high-quality physical LCD screen, and versatile multi-format Universal output sockets, it prevents sudden system failure and critical data corruption during unpredictable power spikes and blackouts.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrue Online Double-Conversion:\u003c\/strong\u003e Constantly filters and regenerates pure electrical waves, providing an absolute 0ms transfer time from mains line to battery reserve when unexpected blackouts happen.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced Power Output (1800W):\u003c\/strong\u003e Offers a 2000VA capacity paired with an optimized 0.9 output power factor, meaning it can deliver more actual wattage to handle power-heavy enterprise server loads safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile C2K UNI Universal Sockets:\u003c\/strong\u003e Equipped with multi-standard Universal output receptacles on the rear panel, accommodating various electrical plug designs without the need for adapters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Quality LCD Multi-View Screen:\u003c\/strong\u003e Displays live diagnostics at a glance, including system operational mode, current load percentages, real-time battery charge levels, input\/output voltage metrics, and internal system fault indicators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Input Range (100V - 300V):\u003c\/strong\u003e Tolerates severe grid instability and brownout valleys without drawing down internal battery power, maximizing your overall battery lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Expansion Slot Capability:\u003c\/strong\u003e Features an open communication port layout supporting optional network configurations like SNMP Management Cards (NMC), CMC, or AS400 dry contact relay cards for remote LAN monitoring.\u003c\/li\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; font-size: 14px; text-align: left;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f9f9f9; border-bottom: 2px solid #e2e2e2;\"\u003e\n\u003cth style=\"padding: 12px 15px; font-weight: bold; width: 35%;\"\u003eComponent Specifications\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; font-weight: bold;\"\u003eTechnical Parameters\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eBrand \u0026amp; Model Series\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eSantak Castle Series - Castle 2K UNI (Tower Type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eNominal Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e2000 VA \/ 1800 Watts (Output Power Factor: 0.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eUPS Topology\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eTrue Online Double-Conversion Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eInput Mains Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e100 VAC – 300 VAC (Single Phase with Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eInput Frequency Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e40 Hz – 70 Hz (Auto-Sensing, Generator Compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eInput Power Factor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e≥ 0.99 at nominal mains condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e220V \/ 230V \/ 240VAC (Tight ± 1% regulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eOutput Waveform\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003ePure Sine Wave (\u0026lt; 1% THDv with pure linear loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eTransfer Intermission Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eMains Mode to Battery Mode: 0 ms | Inverter Mode to Bypass Mode: 4 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eOutput Receptacles\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e4x Multi-Standard UNIVERSAL Sockets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eBattery Cell Parameters\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e4x Internal Maintenance-Free Sealed Lead-Acid (VRLA) 12V \/ 9Ah Batteries (48VDC loop)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eBackup Standby Run Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e\u0026gt; 3.5 Minutes at full 100% load | ~10 Minutes at half 50% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eRecharger Turnaround\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e4 Hours required back up to 90% total system volume capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eInverter Energy Efficiency\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eInverter\/Line Mode: \u0026gt; 91% | ECO Power Saving Mode: 97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eSystem Communications\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eBuilt-in RS232 Interface Port + 1x Open Intelligent Slot for expansion cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eOperational Environment\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003eTemperature: 0 - 40°C | Noise level less than 40dB at a 1-meter front boundary radius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"border-bottom: 1px solid #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px 15px; font-weight: 600; background-color: #fafafa;\"\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px;\"\u003e190 x 399 x 327 mm (W x D x H) | Net Weight: Approx. 17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/ul\u003e","brand":"SANTAK","offers":[{"title":"Default Title","offer_id":38206444798103,"sku":"C2K UNI","price":3500000.0,"currency_code":"MMK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0513\/8205\/9159\/files\/santak-castle-2k-online-ups-c2k-uni-front_jpg.jpg?v=1782981634","url":"https:\/\/ict.com.mm\/my\/products\/santak-castle-2k-online-ups-c2k-uni","provider":"ICT.com.mm","version":"1.0","type":"link"}